Restaurant kitchens use the most water. Blocked drains smell and hurt hygiene. What must drainage design get right? CHINENG explains.

Drainage design notes
1. Odor, rodent, and insect control: cover channels with traps; use screened floor drains; fit steel/copper rodent screens at sewer outlets with bars too tight for mice.
2. Provide floor drains in pantry and cold rooms (brass/stainless covers); put a drain trough at ice-machine fronts.
3. Channel depth is often limited (~300 mm sumps); width by flow; slope preferably >0.5%; length ideally <10 m.
4. Drop the kitchen slab ≥30 cm for channels; add a catch basket before the main drain.
5. Line channel sides with white tile or stainless; waterproof thoroughly.
6. Place stacks beside the heaviest fixtures without blocking work.
7. Oil separation: oily kitchen waste needs grease interceptors—preferably stainless units with baskets for solids.
8. Provide secondary grease treatment before municipal sewers; units may sit on floor or in the dropped slab.
9. Keep branch runs short to stacks or vent them.
10. Heat-resistant plastic in dropped slabs; cast iron elsewhere as required.
11. Open channels drain and clean easily but can smell; closed drains look cleaner and free equipment layout but clean harder.
Sewer detailing
1. Avoid undersized equipment wastes—prefer DN50–DN75; floor discharge clears faster.
2. Corrosion-resistant, anti-slip floors slope ~1% to open channels with rounded bottoms.
3. Leave capacity spare for future expansion—pipes are hard to enlarge later.
CHINENG offers free commercial kitchen design schemes on request.